Kuvaus
8 partition and 8-32 zone Grade 2 intruder alarm panel with integrated GSM communicator
Panel features:
- Message transmission through GPRS to the main or backup IP addresses. If GRPS connection is lost, messages are sent with SMS messages
- Constant control of connection with ARC
- Information about events to users with SMS messages or telephone calls
- Port for connecting additional radio VHF/UHF, Ethernet or GSM transmitters
- Remote configuration, control and update from ARC
- Control with our Protegus keypads or with Paradox K32, K636, K10V keypads, mobile apps, phone call, SMS or iButton key
- Support for temperature sensors
- 2 x SIM
Specifications
| Conformity | Grade 2, EN50131-3, EMC, Low Voltage, RTTE, RoHS |
| Partitions | 8 |
| Inputs | 8, of NC, NO or EOL=2.2 kΩ type |
| Expandable up to 32 with input expansion modules | |
| Zones | 9 types (ON/OFF, Delay, Interior, Interior STAY, Instant, Instant STAY, 24 hours, Fire, Silent) including two-wire fire zone |
| Number of system expanders | Up to 16, including keypads and additional alarm transmitters |
| PGM outputs | 5, OC type (3×0.5A, 1x1A, 1×0.1A) |
| Guard modes | 4, ARM / STAY / STAY DELAY / OFF |
| Zone bypass function | Yes |
| Number of control codes | 1 Master, and up to 39 User codes,
1 Administrator, 1 Installer, and 1 Alarm Receiving Centre |
| Means of control | Trikdis Protegus keypads or Paradox K32, K636, K10V keypads, mobile apps, phone call, SMS, iButton key or other device |
| Temperature sensor support | Yes |
| GSM modem | Quad-Band 850 / 900 / 1800 / 1900 MHz |
| Communication with ARC | Via GPRS (TCP/IP or UDP/IP) or with SMS messages |
| Supported protocols | TRIKDIS TRK or SIA DC-05 Contact ID |
| Encoding format | Contact ID with additional encoding algorithm |
| SMS messaging to users | SMS messages with pre-set customized text to up to 5 telephone numbers |
| Calling to users | Calling immediately after pre-set event to up to 2 telephone numbers |
| Event log | Yes, up to 2000 events |
| Internal clock | Yes |
| MCI bus | Yes, for an additional alarm transmitting device (G10, E10, T10 series) |
| Module configuration | Via USB port using program TrikdisConfig or via GPRS from ARC |
| Power supply | AC 16-18 V or DC 16-24 V |
| Current usage | Up to 80 mA (stand-by)
Up to 150 mA (transmitting) |
| Operating temperature | From -25 ºC to +50 ºC, when relative air humidity 80 % with 20 ºC |
| Dimensions | 130 x 65 x 25 mm (just PCB) |
| Weight | 0.10 kg |
ARC – Alarm Receiving Centre





Arviot